In early tests, Bright Saver frameless plug-in solar panels perform as well as our existing Silfab solar panels.
Bright Saver’s plug-in solar kit contains two 180 W frameless solar panels, an inverter, and some cable ties for mounting the panels on a balcony or fence. Two Bright Saver panels (2 x 180 = 360 W) is equivalent to one traditional solar panel, such as our existing Silfab 360 W panels.
We have 12 Silfab panels on our roof here in Bakersfield, California. Eight panels face east and four face south. After five years of monitoring, the Silfab panels generate, on average, 500 kWh per panel per year or ~6,000 kWh per year in total.
Since electrifying our house and removing the fossil gas line, we need an additional 2,000 kWh per year or the equivalent of four standard size panels.
To begin making up the difference, I ordered two Bright Saver kits for a total 720 W and two sets of aluminum mounting frames. The two kits are equivalent to two traditional panels.
I’ve installed the two kits temporarily to experiment with their production and performance. One two panel set is installed facing south on the car port at 35 degrees for our latitude. The other two panel kit is installed on the east-facing roof of our garage.
As expected the south-facing panels perform better than those facing east. Over a period of five days, the south-facing panels almost reached their rated capacity on the 19 November. During the same day, the east-facing panels only generated ~50% of their rated capacity.

During the same day, the two Bright Saver kits produced as much per kW of installed capacity as our existing Silfab panels. The Bright Saver panels also produced the same number of kWh per standard panel. On average during five days in November, the Bright Saver panels performed as well as the Silfab panels. This confirms my estimation that we will need the equivalent of four standard-size panels to zero out our net consumption.

Expansion Limited by Utilities
Unfortunately, California electric utilities have been effective in limiting how much additional capacity we can add without being moved to an unfavorable rate plan. In California we are limited to adding only 10% of our existing capacity or one kW, whichever is greater. (See NEM 3.0 in California: How Solar Billing Works (FAQ).) As a result, we will be limited to adding only one more Bright Saver two panel kit.
However, it might be possible to add additional solar while limiting the peak output from the inverter. Peak generation occurs only a few minutes every day. So it may be possible to shave off the peak to maximize actual kWh production while staying within the 1 kW capacity limit. Some solar pioneers are experimenting with this approach.